Werkborg Proof Lab

See what the local Service Intake test does and does not prove

The Proof Lab shows three frozen scenarios with an evidence ID, version, date, input class, expected outcome, local outcome and explicit evidence boundary, alongside the interactive local control flow.

Intended delivery

A reviewable local demonstration with enough context to assess the outcome and its limitations.

Evidence required before delivery

  • Three evidence cards from calibration and holdout sets with date, version, environment and expected result.
  • An interactive local flow with field source, role decision, kill switch and audit export.
  • Failure and stop routes plus an explicit statement of what was not proven.

Authority boundary

What this solution explicitly does not promise

  1. 01

    Example data is clearly labelled and does not constitute a customer case.

  2. 02

    One test is not a general guarantee of performance, savings or production availability.

Three inspectable test scenarios

Expected and local outcome side by side

CAL-0001

Complete report

CALIBRATION · READY_FOR_HUMAN_REVIEW · 2026-08-01

Input
Customer, location, asset, serial number and issue are present.
Expected
A local work-order draft is ready for human review.
Local outcome
The deterministic adapter structures fields and creates a draft only.
Excluded
No message sent and no external record created.
CAL-0005

Missing serial number

CALIBRATION · MISSING_INFORMATION · 2026-08-01

Input
The report includes a maintenance request and asset but no serial number.
Expected
No complete intake; a question draft or human addition only.
Local outcome
The field remains visibly missing and the route requests completion.
Excluded
No automatic schedule or customer promise.
HLD-0009

Possible safety signal

HOLDOUT · BLOCKED_SAFETY · 2026-08-01

Input
The report mentions an unusual smell near an installation.
Expected
Fail-closed hand-off to a person; approval is unavailable.
Local outcome
The local stop rule blocks the normal draft route and records escalation.
Excluded
No safety diagnosis or autonomous urgency decision.
  • Local test
  • Sample data
  • No customer outcome
  • No production connector

Working control flow · sample data only

Run a new service report through the local operator

The local control adapter extracts fields from new text, applies stop rules, creates a draft only and keeps a privacy-light audit on this device.

This proves the workflow, policy, export and stop logic. It is not a customer case, model-quality test or production connector.

READY_LOCAL
  1. 1Received
  2. 2Checked
  3. 3Waiting for person
  4. 4Decision recorded
New local inputWB-2026-071

Control adapter ready

Edit the sample text and process it again; the outcome is calculated from the current input.

Traceable local evidence

Local audit log

Up to 50 privacy-light records stay in localStorage; the report text itself is not stored.

No local audit record yet.

The browser demo uses sample data and a deterministic control adapter only. Real model quality, Microsoft 365/Syntess integrations and external write actions remain separately blocked until a customer tenant, provider choice and acceptance test exist.

Next step

Start with one provable workflow.

No generic AI presentation. Bring volume, systems, exceptions and the human decision-maker.

Prepare a demo conversation